Description

Residual Current Breaker HiSmart NV821938 is a 4-pole RCBO rated at 20 A with 30 mA residual sensitivity. It combines overcurrent (class C) and earth-leakage protection in a single device to detect leakage currents and disconnect supply, reducing the risk of electric shock and fire in residential and light commercial installations. The unit is designed for DIN-rail mounting and supports cable or pin-type busbar connections.

Advantages

This HiSmart NV821938 RCBO provides combined protection against overloads, short circuits and earth leakage with a breaking capacity of 6 kA. Features include an anti-mistake contact terminal block, flame-retardant and high-temperature resistant housing, impact resistance, and clear contact-position indication (red = closed, green = open). It supports top connection and accommodates conductors or busbars up to 35 mm².

Suitable for

  • Residential electrical distribution boards requiring 4-pole protection
  • Small commercial installations where 30 mA earth leakage sensitivity is needed
  • Circuits that require combined overcurrent (class C) and residual-current protection

Key specifications

  • Number of poles: 4
  • Rated current (In): 20 A
  • Trip characteristic: Class C
  • Rated sensitivity: 30 mA
  • Rated voltage (Ue): AC 230 V
  • Rated short-circuit capacity (Icn): 6000 A
  • Rated impulse withstand voltage (Uimp): 4000 V
  • Insulation voltage (Ui): 500 V
  • Frequency: 50/60 Hz
  • Break time: <= 0.1 s
  • Mechanical life: 10,000 operations; Electrical life: 4,000 operations
  • Protection rating: IP20
  • Connection type: cable / pin-type busbar, top connection
  • Wire/busbar cross-section: up to 35 mm²
  • Mounting: DIN rail EN 60715 (35 mm)
  • Operating temperature: -25 °C to +70 °C
  • Dimensions: 82 x 72 x 78 mm
  • Standards: IEC 61009-1 / EN 61009-1
  • Warranty: 24 months

How to use

Install the HiSmart NV821938 on a standard 35 mm DIN rail according to local electrical codes. Make top connections using appropriate cables or a pin-type busbar, ensuring conductor cross-sections do not exceed 35 mm². Verify correct polarity and tighten terminals to the manufacturer’s torque specifications. Use the contact-position indication to confirm the device state (red = closed, green = open) and test the unit after installation to ensure correct tripping at leakage currents.

Recommendations

Mount and commission this RCBO only by qualified personnel. Periodically test residual-current operation according to local regulations and the manufacturer’s instructions to maintain protection performance.

How to use

Install the HiSmart NV821938 on a standard 35 mm DIN rail according to local electrical codes. Make top connections using appropriate cables or a pin-type busbar, ensuring conductor cross-sections do not exceed 35 mm². Verify correct polarity and tighten terminals to the manufacturer’s torque specifications. Use the contact-position indication to confirm the device state (red = closed, green = open) and test the unit after installation to ensure correct tripping at leakage currents.

Recommendations

Mount and commission this RCBO only by qualified personnel. Periodically test residual-current operation according to local regulations and the manufacturer’s instructions to maintain protection performance.

Points clés
  • Residential electrical distribution boards requiring 4-pole protection
  • Small commercial installations where 30 mA earth leakage sensitivity is needed
  • Circuits that require combined overcurrent (class C) and residual-current protection
  • Number of poles: 4
  • Rated current (In): 20 A
  • Trip characteristic: Class C
  • Rated sensitivity: 30 mA
  • Rated voltage (Ue): AC 230 V
  • Rated short-circuit capacity (Icn): 6000 A
  • Rated impulse withstand voltage (Uimp): 4000 V
  • Insulation voltage (Ui): 500 V
  • Frequency: 50/60 Hz
  • Break time:
  • Mechanical life: 10,000 operations; Electrical life: 4,000 operations
  • Protection rating: IP20
  • Connection type: cable / pin-type busbar, top connection
  • Wire/busbar cross-section: up to 35 mm²
  • Mounting: DIN rail EN 60715 (35 mm)
  • Operating temperature: -25 °C to +70 °C
  • Dimensions: 82 x 72 x 78 mm
  • Standards: IEC 61009-1 / EN 61009-1
  • Warranty: 24 months
Historique des prix des 6 derniers mois
Interrupteur différentiel HiSmart NV821938 4P 20A 30mA
Actuel
38,32 €
Le plus bas 7 j
37,78 €
Le plus haut 7 j
38,32 €
Variation 24 h
0,00 €   0%
Variation 7 j
+0,54 €   +1%
Variation 30 j
0,00 €   0%

Écrire un avis

Note *
Remarque : le code HTML n’est pas interprété.

Même gamme et alternatives

7

Produits populaires dans cette catégorie

8
Vendeur / Verkäufer : UAB KUR LT · Gariūnų g. 57-14, LT-02300 Vilnius, Lituanie / Litauen · N° d’entreprise / Firmennummer 303192950 · N° TVA / USt-IdNr. LT100008198612 · Expédition depuis l’UE (Lituanie) / Versand aus der EU (Litauen)
WhatsApp
Messenger
Bonjour, je suis l’assistant IA de DistriNode. Je peux vous aider à trouver des produits, comparer des options, créer des devis PDF ou ouvrir des demandes d’assistance.
Toutes les catégories